Todos los puertos bloqueados tapón de cavidad

Capacidad: | Cavidad: T-162A
XZCA : Todos los puertos bloqueados  tapón de cavidad
Technical Features [ + ]

This cavity plug blocks all ports.

Technical Data [ + ]
Notar: Los datos pueden variar según la configuración . Consulte la sección de CONFIGURATION
cavidad T-162A
Series 0
Maximum Operating Pressure 5000 psi350 bar
Port Configuration 2 Port2 Port
Valve Hex Size 3/4 in.19,1 mm
Valve Installation Torque 20 - 25 lbf ft27 - 33 Nm
Seal kit - Cartridge Buna: 990162007
Seal kit - Cartridge Polyurethane: 990162002
Seal kit - Cartridge Viton: 990162006
FAQs [ + ]

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

Only external seals are serviceable.  Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.