12 VDC coil with Metri-Pack, Series 150-2M connector with TVS Diode

770812 : 12 VDC coil with Metri-Pack, Series 150-2M connector with TVS Diode
Technical Features [ + ]
  • A TVS surge suppression diode is built into DC coils. Nominal breakdown voltage: 68V. Model code 1.5 KE68CA Steady state power dissipation @ 75°C is 6.5 W and peak pulse dissipation is 1500 W for 1 ms, nonrepetitive.
  • Power cable with mating connector is required and is not included with product.
  • Coil windings utilize Class N, (392° F [200 °C] rated) magnet wire.
  • The Metri-Pack, Series 150-2M connector satisfies the requirements of thermal shock tests. In this test, the coil is energized to achieve its stabilized temperature and then immediately immersed into ice cold water. This process is repeated 5 times, after which, the insulation resistance of the coils should not fall below 10 megaohms.
  • For optimum proportional performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
  • IP rating is dependent on the coil connector and the mating connector used.
  • The external steel shell is plated with clear zinc trivalent.
  • RoHS compliant. Restricted materials less than 0.1% total by weight.
Technical Data [ + ]
Maximum Coil Temperature at 68ºF (20ºC) Ambient 218ºF (105ºC)218ºF (105ºC)
Arc Suppression (TVS) IncludedIncluded
Power Consumption (cold) - at rated voltage 22 watts22 watts
Maximum Ambient Temperature 122 °F50 °C
Voltage/Frequency 12 VDC12 VDC
Operating Voltage Range +/- 10% nominal+/- 10% nominal
Duty Cycle Rating 100 %100 %
Connector Metripack Series 150-2MMetripack Series 150-2M
Connector Environment Rating IP69KIP69K
Solenoid Tube Diameter .75 in.19 mm
Coil Nut Torque 4.5 lbf in.0,5 Nm
Proportional Performance Data [ + ]
Maximum Current 1150 mA1150 mA
Nominal Coil Resistance at 122ºF (50ºC) Stabilized 9.4 ±8% ohms9.4 ±8% ohms
Nominal Coil Resistance at 68ºF (20ºC) Cold 6.4 ±8% ohms6.4 ±8% ohms
Used With [ + ]

What models can this kit be used with?

  • DAAL
    2-way, solenoid-operated directional spool valve - pilot capacity
  • DAALS
    2-way, soft shift, solenoid-operated directional spool valve - pilot capacity
  • DBAL
    3-way, solenoid-operated directional spool valve - pilot capacity
  • DBALS
    3-way, soft shift, solenoid-operated directional spool valve - pilot capacity
  • DFCA
    2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2
  • DFCB
    2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1
  • DFDA
    2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2
  • DFDB
    2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1
  • DFEA
    2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2
  • DFEB
    2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1
  • DFFA
    2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2
  • DFFB
    2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1
  • DLDA
    2-way, solenoid-operated directional spool valve
  • DLDAS
    2-way, soft shift, solenoid-operated directional spool valve
  • DLDAZ
    2-way, solenoid-operated directional spool valve with position switch
  • DMDA 3-way, solenoid-operated directional spool valve
  • DMDAS 3-way, soft shift, solenoid-operated directional spool valve
  • DMDAZ
    3-way, solenoid-operated directional spool valve with position switch
  • DNCA 4-way, 2-position, solenoid-operated directional spool valve with closed transition
  • DNCAZ
    4-way, 2-position, solenoid-operated directional spool valve with closed transition and position switch
  • DNDA 4-way, 2-position, solenoid-operated directional spool valve
  • DNDAS 4-way, 2-position, soft shift, solenoid-operated directional spool valve
  • DNDC 4-way, 3-position, solenoid-operated directional spool valve
  • DNDY 2-position, 6-way, solenoid-operated directional spool valve
  • DNDYS 2-position, 6-way, soft shift, solenoid-operated directional spool valve
  • DTCA
    2-way, direct-acting, solenoid-operated directional blocking poppet valve with overlap
  • DTCAZ
    2-way, direct-acting, solenoid-operated directional blocking poppet valve with overlap and position switch
  • DTDA
    2-way, direct-acting, solenoid-operated directional blocking poppet valve
  • DTDAS
    2-way, direct-acting, soft shift, solenoid-operated directional blocking poppet valve
  • DWDA
    3-way, direct-acting, solenoid-operated directional poppet valve
  • FMDA Electro-proportional 3-way flow control valve, meter in
  • FMDB Electro-proportional 3-way flow control valve, meter in
  • FPCC Electro-proportional flow control valve - normally closed
  • FPCH Electro-proportional flow control valve - normally open
  • FPFK Pilot-operated, normally closed, electro-proportional throttle with reverse flow check
  • FPHK Pilot-operated, normally closed, electro-proportional throttle with reverse flow check
  • HDDA 2-way, solenoid-operated directional poppet valve - after check
  • PRDL
    Electro-proportional, direct-acting, pressure reducing/relieving valve with open transition
  • PRDM Electro-proportional, direct-acting, pressure reducing/relieving valve with open transition - high pressure setting with no command
  • PRDN Electro-proportional, direct-acting, pressure reducing/relieving valve, high pressure setting with no command
  • PRDP
    Electro-proportional, direct-acting, pressure reducing/relieving valve
  • PSDL Electro-proportional, direct-acting, pressure reducing/relieving valve with open transition and drain to port 4
  • PSDP Electro-proportional, direct-acting, pressure reducing/relieving valve with drain to port 4
  • RBAN Electro-proportional relief valve - pilot capacity, high pressure setting with no command
  • RBAP Electro-proportional relief valve - pilot capacity