24 VDC coil with IR embedded power saver
Technical Features [ + ]
The Power Saver is a compact, low profile coil/controller combination for use with switching solenoid valves. The Power Saver controls current to the coil to minimize power consumption. Bright LED indicators on the unit provide an overview of the operating status. Setup is accomplished through Sun's Amplifier Set Up Software or the Hand Held Programmer (HHP). There is no cover to remove and no tiny pots to set. Once configured, the settings are stored in permanent memory within the unit. The Power Saver is intended for use on continuous duty applications (minimum switches between on and off).
- Easily configured using Sun's Amplifier Set Up Software or the Hand Held Programmer.
- LED indication of Status and Output Current
- Adjustable current limited output with short circuit protection
- Microprocessor controlled for consistent, reliable performance
- Deutsch DT04-6P Connector, IP69K rated
- All output limits are independently adjustable.
- Glass filled nylon enclosure with Lexan light pipes and polyurethane potting compound
- Power cable with mating connector is required and is not included with product.
- CE approved - See CE Testing Results and Explanation, document number 999-991-260, for details
Technical Data [ + ]
Supply Voltage | Equals coil voltage within +/-10%Equals coil voltage within +/-10% |
Supply Current | I(sol) + 20mAI(sol) + 20mA |
Operating Temperature Range | -4 to 158 °F-20 to 70 °C |
Analog Input Impedance | 13 Kilo-ohms13 Kilo-ohms |
Card Function | Power SaverPower Saver |
Output Current for 6 seconds (max.) | 2000 mA2000 mA |
Output Current for holding (max.) | 1600 mA1600 mA |
Voltage/Frequency | 24 VDC24 VDC |
Connector | Deutsch DT04-6PDeutsch DT04-6P |
Used With [ + ]
What models can this kit be used with?
- DAALS2-way, soft shift, solenoid-operated directional spool valve - pilot capacity
- DBALS3-way, soft shift, solenoid-operated directional spool valve - pilot capacity
- DFDA2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2
- DLDAS2-way, soft shift, solenoid-operated directional spool valve
- DMDA 3-way, solenoid-operated directional spool valve
- DMDAS 3-way, soft shift, solenoid-operated directional spool valve
- DNCA 4-way, 2-position, solenoid-operated directional spool valve with closed transition
- DNDA 4-way, 2-position, solenoid-operated directional spool valve
- DNDAS 4-way, 2-position, soft shift, solenoid-operated directional spool valve
- DNDC 4-way, 3-position, solenoid-operated directional spool valve
- DNDY 2-position, 6-way, solenoid-operated directional spool valve
- DNDYS 2-position, 6-way, soft shift, solenoid-operated directional spool valve
- DTCA2-way, direct-acting, solenoid-operated directional blocking poppet valve with overlap
- HDDA 2-way, solenoid-operated directional poppet valve - after check
- 991700Hand Held Programmer
- 991702 Infrared cable adapter
- 991704 USB infrared cable adapter
- 991706003 Deutsch DT06-6S cable assembly
- 991706006 Deutsch DT06-6S cable assembly
Notes [ + ]
- A source type input is required. A sinking type analog input will damage the amplifier.
Additional Resources [ + ]
Technical Tips
Technical Information
- Electro-Hydraulic Terms and Definitions (2.94 MB)
- Environmental Test Specification for Electrical and Electronic Co (254.61 KB)
- Sun's Floating Style Screw-In Cartridge (1.06 MB)
- CE Declaration of Conformity - XMD 12-2017 (133.69 KB)
- CE Testing Results and Explanation; 999-991-260 (51.97 KB)
Literature