Momentary/twist operation, manual override control kit, T control
The momentary/twist manual override is a rotary, hand-actuated device for use on Sun's full flow solenoid valves and certain Series P models. The hand knob is constructed of a reinforced plastic for durability, heat resistance and stability in varying environmental conditions and is suitable for operation with a gloved hand. The override assembly incorporates a sealed-construction design thereby preventing the introduction of debris and other damaging contamination. Once installed on a Sun solenoid valve, the override feature allows the operator to manually shift the de-energized valve. Solenoid cartridges may be ordered in this configuration by specifying a "T" control in the cartridge model number. Sun kits for field conversion are also available. Please note that valves with the momentary/twist manual override are not suitable for load holding applications.
- The momentary/twist override option "T" allows the operator to momentarily shift the valve by twisting the manual override clockwise and releasing. Once released, the valve returns to its de-energized position.
- The manual control assembly has a mechanical life expectancy of approximately 7,000 cycles.
Material | Black plastic and aluminumBlack plastic and aluminum |
Description | Momentary/Twist Operation (Option T)Momentary/Twist Operation (Option T) |
Operating Torque | 10 lbf in.1,2 Nm |
What models can this kit be used with?
- DAAL2-way, solenoid-operated directional spool valve - pilot capacity
- DAAM 2-way, manually operated, spool directional valve - pilot capacity
- DBAL3-way, solenoid-operated directional spool valve - pilot capacity
- DBAM 3-way, manually operated, spool directional valve - pilot capacity
- DFCA2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2
- DFCB2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1
- DFDA2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2
- DFDB2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1
- DFEA2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2
- DFEB2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1
- DFFA2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2
- DFFB2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1
- DLDA2-way, solenoid-operated directional spool valve
- DLDM 2-way, manually operated, directional spool valve
- DMDA 3-way, solenoid-operated directional spool valve
- DMDM 3-way, manually operated, directional spool valve
- DNCA 4-way, 2-position, solenoid-operated directional spool valve with closed transition
- DNDA 4-way, 2-position, solenoid-operated directional spool valve
- DNDM 4-way, manually operated, directional spool valve
- DNDY 2-position, 6-way, solenoid-operated directional spool valve
- DNDYS 2-position, 6-way, soft shift, solenoid-operated directional spool valve
- DTCA2-way, direct-acting, solenoid-operated directional blocking poppet valve with overlap
- DTCM 2-way, manually operated, directional poppet valve with overlap
- DTDA2-way, direct-acting, solenoid-operated directional blocking poppet valve
- DTDM 2-way, manually operated, directional poppet valve
- DWDA3-way, direct-acting, solenoid-operated directional poppet valve
- DWDM 3-way, manually operated, directional poppet valve
- FMDA Electro-proportional 3-way flow control valve, meter in
- FMDB Electro-proportional 3-way flow control valve, meter in
- FPCC Electro-proportional flow control valve - normally closed
- FPCH Electro-proportional flow control valve - normally open
- HDDA 2-way, solenoid-operated directional poppet valve - after check
- Ensure o-ring is installed in bottom of the manual override assembly.
- Remove existing coil nut from end of solenoid tube.
- Thread the manual override assy on to the end of the solenoid tube. Point coil connector in desired position before hand tightening the manual override assy.
- Note: Thread lock may be used if anticipated conditions warrant.