P to T, side ports

Function

Function for CSE: Air-Bleed and Start-up
Air-Bleed and Start-up
Function for CSE: Relief, P to T
Relief, P to T
Port Designators [ + ]
Modifiers Ports
CSE Ports A, B, P, T: 1" NPTF; Ports X & Y: 1/4" NPTF; Gage Port: 1/4" NPTF;
Technical Data [ + ]
Body Type SubplateSubplate
Interface ISO 08ISO 08
Body Features P to T, side portsP to T, side ports
Mounting Hole Diameter .41 in.10,4 mm
Mounting Hole Depth ThroughThrough
Mounting Hole C'bore Diameter .59 in.15,0 mm
Mounting Hole C'bore Depth .56 in.14,2 mm
Mounting Hole Quantity 22
Open Cavities 11
Cavity T-3A
Port Size 1" NPTF1" NPTF
FAQs [ + ]

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

Notes [ + ]
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.
Additional Resources [ + ]