2-way, solenoid-operated directional spool valve with position switch

Capacity: 12 gpm45 L/min. | Cavity: T-13A
Technical Features [ + ]

This solenoid-operated 2-way, 2-position cartridge is a direct-acting, balanced spool directional valve. The valve is available in either a normally open or normally closed configuration.

The position switch provides confirmation that the valve is in the spring biased position. Click Here for the position sensor pin diagram

  • A coil must be ordered with this cartridge. This cartridge is supplied as a sealed, factory set unit and is not field serviceable. If the assembly requires changes or service it needs to be returned to the factory. Any tampering will violate the product warranty.
  • Position switch is CE approved.
  • When torquing this cartridge into its cavity, a crow's foot wrench or similar will be required since the position switch precludes the use of a deep socket wrench.
  • The solenoid tube assembly is fatigue rated for 5000 psi (350 bar) service.
  • This valve is direct actuated and requires no minimum hydraulic pressure for operation.
  • This valve utilizes a wet armature design. This means that the working fluid surrounds the armature and is exposed to the heat generated by the coil. This can be a factor if the coil is energized for long periods of time. Some fluids, notably water/glycol mixtures, break down at these temperatures over time and form varnishes that will affect the function of the cartridge.
  • A wide variety of coil termination and voltage options are available, with and without surge protection. See the CONFIGURATION section.
  • The solenoid's unique magnetic design results in a high efficiency solenoid, yielding high spool actuating force per Watt expended, leading to reliable valve shifting.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
Technical Data [ + ]
Note: Data may vary by configuration. See CONFIGURATION section.
Cavity T-13A
Series 1
Capacity 12 gpm45 L/min.
Maximum Operating Pressure 5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 5 in³/min.@3000 psi80 cc/min.@210 bar
Response Time - Typical 50 ms50 ms
Switching Frequency 15,000 max. cycles/hr15,000 max. cycles/hr
Solenoid Tube Diameter .75 in.19 mm
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm
Model Weight .50 lb0,25 kg
Seal kit - Cartridge Buna: 990413007
Seal kit - Cartridge Viton: 990413006
Switch Specifications [ + ]
Note: Data may vary by configuration. See CONFIGURATION section.
Supply Voltage 20-30 VDC20-30 VDC
Operating Temperature Range -25 to 80 °C-25 to 80 °C
Vibration ≥ 50g, 0-500 impulses/sec≥ 50g, 0-500 impulses/sec
Shock >50 g, 1ms>50 g, 1ms
Reverse Polarity Protection YesYes
Maximum Output Load ≤ 400 mA, Duty Ratio 100%≤ 400 mA, Duty Ratio 100%
Short Circuit Protection Yes, Load Short UnlimitedYes, Load Short Unlimited
Turn On Time ≤ 25 ms≤ 25 ms
Hysteresis ≤ .002 in.≤ .002 in.
Thermal Shift - 0 to 80 °C ≤ ± .004 in.0,1 mm
EMC DIN EN 61000-6-1/2/3/4DIN EN 61000-6-1/2/3/4
Connector M12 X 1 (4) PinM12 X 1 (4) Pin
Connector Environment Rating IP65IP65
Performance Curves [ + ]
FAQs [ + ]

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.

Only external seals are serviceable.  Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.
Notes [ + ]
  • An additional 2.00 inches (50,8 mm) beyond the valve extension is needed for coil installation and removal.
Additional Resources [ + ]
Coil Information [ + ]