2-way, pilot shifted, dual path, proportional throttle with position switch

Capacity: 15 gpm60 L/min. | Cavity: T-52AD
FTCAZ : 2-way, pilot shifted, dual path, proportional throttle with position switch
Technical Features [ + ]

This valve is a 2-way, 2-position proportional throttle. Ports 2 and 3 are normally closed. Pilot pressure at port 1 creates a metering orifice between port 2 and 3 that is proportional to the pressure at 1. The metering passage is self-compensating.

This valve uses a dual-path design. Ports 2 and 3 incorporate a double-port area.

This valve incorporates a position switch to provide confirmation that the valve is closed.

  • This cartridge is supplied as a sealed, factory set unit and is not field serviceable. Any tampering will violate the product warranty.
  • Position switch is CE approved.
  • When torquing this cartridge into its cavity, a crow's foot wrench or similar will be required since the position switch precludes the use of a deep socket wrench.
  • These valves may be pressure compensated by an external, modulating, logic element. Use LR_C-XHN for a bypass circuit or LP_C-XHN for a restrictive circuit.
  • The valve provides a degree of self-compensation and may be used as a flow control. To increase the accuracy of flow control, an external, modulating, logic element can be used to maintain a constant flow over a wider range of flows and pressures. See performance curves for additional information.
  • An optional protective cover, with mounting hardware included, may be ordered separately. See kit number: 991-043.
  • Ports 1 and 4 should be limited to 500 psi (35 bar).
  • Pressure at port 4 directly opposes pressure at port 1.
  • Accurate pressure compensated control requires that a constant pressure differential be maintained across the valve.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
Technical Data [ + ]
Note: Data may vary by configuration. See CONFIGURATION section.
Cavity T-52AD
Series 2
Capacity 15 gpm60 L/min.
Pilot Pressure Required to Shift Valve 60 - 130 psi4 - 9 bar
Pilot Pressure Required for Full Shift at Rated Flow 290 - 340 psi20 - 23 bar
Maximum Operating Pressure 5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 5 in³/min.@1000 psi80 cc/min.@70 bar
Pilot Volume Displacement .05 in³0,82 cc
Valve Hex Size 1 1/8 in.28,6 mm
Valve Installation Torque 45 - 50 lbf ft61 - 68 Nm
Model Weight 1.90 lb0,85 kg
Seal kit - Cartridge Buna: 990152007
Seal kit - Cartridge Viton: 990152006
Switch Specifications [ + ]
Note: Data may vary by configuration. See CONFIGURATION section.
Supply Voltage 20-30 VDC20-30 VDC
Operating Temperature Range -25 to 80 °C-25 to 80 °C
Vibration ≥ 50g, 0-500 impulses/sec≥ 50g, 0-500 impulses/sec
Shock >50 g, 1ms>50 g, 1ms
Reverse Polarity Protection YesYes
Maximum Output Load ≤ 400 mA, Duty Ratio 100%≤ 400 mA, Duty Ratio 100%
Short Circuit Protection Yes, Load Short UnlimitedYes, Load Short Unlimited
Turn On Time ≤ 25 ms≤ 25 ms
Hysteresis 35 %35 %
Thermal Shift - 0 to 80 °C ≤ ± .004 in.0,1 mm
EMC DIN EN 61000-6-1/2/3/4DIN EN 61000-6-1/2/3/4
Connector M12 X 1 (4) PinM12 X 1 (4) Pin
Connector Environment Rating IP65IP65