先导式, 减压阀

流量: 5 gpm20 L/min. | 插孔: T-163A
PBBB : 先导式, 减压阀
技术特性 [ + ]

先导控制式,减压阀将进口(口2)高压主油路压力调节减至口1所需的减压压力,这样可以利用单一泵源实现多种压力需求的油路。

  • 从减压压力口(口1)到进口(口2)的反向液流可能导致主阀芯关闭。如果油路中需要反向自由流,可以考虑在油路中加入单向阀。
  • 所有弹簧范围的最小设定值为75 psi (5 bar)。
  • 先导式操作阀具有非常平坦的压力/流量特性,良好的稳定性和极低的滞回。
  • 口3处的压力直接以1:1的比例增加到阀的设定值上,且压力不能超出5000 psi(350 bar)。
  • 推荐最大进口压力和设定范围选项有关。选项A,B,N,Q在进出口压差最高3000 psi (210 bar)条件下测试。选项W在进口压力5000 psi (350 bar)下测试。
  • 利用Sun浮动结构减少由于过量安装扭矩或插孔/插装阀加工误差带来的内部零件粘结的可能性。
技术数据 [ + ]
注意:技术参数可能因产品配置而不同。请查看产品配置部分。
插孔 T-163A
系列 0
通流能力 5 gpm20 L/min.
最大操作压力 5000 psi350 bar
工厂默认的设定值 blocked control port (dead headed)blocked control port (dead headed)
控制先导流量 7 - 10 in³/min.0,11 - 0,16 L/min.
调节 - 从最小设定到最大设定的顺时针圈数 55
阀头部安装六角尺寸 3/4 in.19,1 mm
阀安装扭矩 20 - 25 lbf ft27 - 33 Nm
调节螺栓的内六角尺寸 5/32 in.4 mm
锁紧螺母六角尺寸 1/2 in.12,7 mm
锁紧螺母力矩 80 - 90 lbf in.9 - 10 Nm
型号重量 .30 lb0,15 kg
Seal kit - Cartridge Buna: 990163007
Seal kit - Cartridge Polyurethane: 990163002
Seal kit - Cartridge Viton: 990163006
性能曲线 [ + ]
常见问题 [ + ]

Our reducing valves are outside-in valves; the supply pressure on the outside of the working parts is higher than the inside. At some pressure differential, the outside (sleeve) will close in on the piston and cause the valve to stick. A D range is adjustable from 25 to 800 psi with a maximum differential of 2000 psi. This means you could set the valve at 600 psi and expect it to work correctly with a supply pressure of 2600 psi. The valve may work at higher differentials, but we do not recommend it. The W and C ranges are tested over their entire range with an inlet pressure of 5000 psi. All direct-acting valves are tested with an inlet pressure of 5000 psi.

Direct acting valves are used to prevent over pressure and pilot operated valves are used to regulate pressure. If you are unsure, use a direct acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.

设置压力的误差在产品的性能参数页中都有详细说明,您可以通过点击可选产品网页中的更多产品信息到达产品性能参数页面。

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

Yes. A reducing or reducing/relieving valve is normally open. If the pressure in the secondary circuit is less than the setting, it will be open.

2 caveats: (1) If the valve is in the reducing mode and you suddenly reverse the flow, the valve will not have time to open and will shift into relieving mode or (2) If the back flow generates a pressure drop through the valve that exceeds the setting, the valve will shift into the relieving mode.

When in doubt, use a reverse flow check.

Yes. If you look in the sandwich section you will see that we offer many such packages. When you are pressurizing B, A is connected to tank, allowing the reducer to do its job. When you reverse, the drain or tank port of the reducer is pressurized by A. This increases the setting of the reducer and helps keep the reducer open in the reverse flow direction.

Only external seals are serviceable.  Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.