12 VDC aclimatado bobina con Metri-Pack, Series 150-2M conector

773812 : 12 VDC aclimatado bobina con Metri-Pack, Series 150-2M conector
Technical Features [ + ]

This weatherized coil is designed for Sun's full flow switching and electro-proportional cartridges with anticipated exposure to system wash-down or marine environments. This coil is only available with the Metri-Pack Series 150-2M connector along with a choice of (5) voltages; 12 VDC, 14 VDC, 24 VDC, 28 VDC and 36 VDC. The installation of this coil requires an additional weatherization kit and modification to Sun's cavity and is intended for new applications.

Please note: Manual override functionality is not compatible with weatherized coils.

  • Weatherized coils are available in kit form only and cannot be configured with the cartridge.
  • An additional weatherization kit is required with this coil. Weatherization kits are cartridge-model dependent. See the "Used With" tab.
  • A TVS surge suppression diode is built into DC coils. Nominal breakdown voltage: 68V. Model code 1.5 KE68CA Steady state power dissipation @ 75°C is 6.5 W and peak pulse dissipation is 1500 W for 1 ms, nonrepetitive.
  • Coil windings utilize Class N, (392° F [200 °C] rated) magnet wire.
  • Power cable with mating connector is required and is not included with product.
  • Weatherized coil diameter is 4 mm larger than standard 770 series coil.
  • The Metri-Pack, Series 150-2M connector satisfies the requirements of thermal shock tests. In this test, the coil is energized to achieve its stabilized temperature and then immediately immersed into ice cold water. This process is repeated 5 times, after which, the insulation resistance of the coils should not fall below 10 megaohms.
  • For optimum proportional performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
  • IP rating is dependent on the coil connector and the mating connector used.
  • Constructed of an external steel frame, encapsulated with Dupont 77G33L or engineering approved equivalent for weatherization.
  • This weatherized coil is rated for IP69K and 1000 hours of salt spray.
  • RoHS compliant. Restricted materials less than 0.1% total by weight.
Technical Data [ + ]
Maximum Coil Temperature at 68ºF (20ºC) Ambient 218ºF (105ºC)218ºF (105ºC)
Arc Suppression (TVS) IncludedIncluded
Power Consumption (cold) - at rated voltage 22 watts22 watts
Maximum Ambient Temperature 122 °F50 °C
Voltage/Frequency 12 VDC12 VDC
Operating Voltage Range +/- 10% nominal+/- 10% nominal
Duty Cycle Rating 100 %100 %
conector Metripack Series 150-2MMetripack Series 150-2M
Connector Environment Rating IP69KIP69K
Solenoid Tube Diameter .75 in.19 mm
Coil Nut Torque 4.5 lbf in.0,5 Nm
Proportional Performance Data [ + ]
Maximum Current 1150 mA1150 mA
Nominal Coil Resistance at 122ºF (50ºC) Stabilized 9.4 ±8% ohms9.4 ±8% ohms
Nominal Coil Resistance at 68ºF (20ºC) Cold 6.4 ±8% ohms6.4 ±8% ohms
Used With [ + ]

What models can this kit be used with?

  • DAAL
    2-vías , direccional, operada por solenoide carrete válvula - capacidad de pilotaje
  • DAALS
    2-vías , cambio suave , direccional, operada por solenoide carrete válvula - capacidad de pilotaje
  • DBAL
    3-vías, direccional, operada por solenoide carrete válvula - capacidad de pilotaje
  • DBALS
    3-vías, cambio suave , direccional, operada por solenoide carrete válvula - capacidad de pilotaje
  • DFCA
    2-vías , 2-stage, direccional, operada por solenoide disco válvula - caudal 1-2
  • DFCB
    2-vías , 2-stage, direccional, operada por solenoide disco válvula - caudal 2-1
  • DLDA
    2-vías , direccional, operada por solenoide carrete válvula
  • DLDAS
    2-vías , cambio suave , direccional, operada por solenoide carrete válvula
  • DMDA 3-vías, direccional, operada por solenoide carrete válvula
  • DMDAS 3-vías, cambio suave , direccional, operada por solenoide carrete válvula
  • DNCA 4-vías, 2-posiciones , direccional, operada por solenoide carrete válvula con transición cerrada
  • DNDA 4-vías, 2-posiciones , direccional, operada por solenoide carrete válvula
  • DNDAS 4-vías, 2-posiciones , cambio suave , direccional, operada por solenoide carrete válvula
  • DNDC 4-vías, 3-posiciones, direccional, operada por solenoide carrete válvula
  • DNDY 2-posiciones , 6-vías, direccional, operada por solenoide carrete válvula
  • DTCA
    2-vías , acción-directa , direccional, operada por solenoide blocking disco válvula con superponer
  • DTDA
    2-vías , acción-directa , direccional, operada por solenoide blocking disco válvula
  • DTDAS
    2-vías , acción-directa , cambio suave , direccional, operada por solenoide blocking disco válvula
  • DWDA
    3-vías, acción-directa , direccional, operada por solenoide disco válvula
  • FMDA Electro-proporcional 3-vías control de caudal válvula , alimentación regulada
  • FMDB Electro-proporcional 3-vías control de caudal válvula , alimentación regulada
  • FPCC Electro-proporcional control de caudal válvula - normalmente cerrado
  • FPCH Electro-proporcional control de caudal válvula - normalmente abierto
  • PRDL
    Electro-proporcional , acción-directa , reductor/alivio de presión válvula con transición abierta
  • PRDM Electro-proporcional , acción-directa , reductor/alivio de presión válvula con transición abierta - ajuste a alta presión sin comando
  • PRDN Electro-proporcional , acción-directa , reductor/alivio de presión válvula , ajuste a alta presión sin comando
  • PRDP
    Electro-proporcional , acción-directa , reductor/alivio de presión válvula
  • RBAN Electro-proporcional alivio válvula - capacidad de pilotaje, ajuste a alta presión sin comando
  • RBAP Electro-proporcional alivio válvula - capacidad de pilotaje
  • 991055 Cavidad T-11A, aclimatado bobina sello juego
  • 991056 Cavidades T-13A y T-31A, aclimatado bobina sello juego
  • 991057 Cavidad T-31A, aclimatado bobina sello juego
  • 991058 Cavidades T-8A y T-9A, aclimatado bobina sello juego
  • 991059 Cavidad T-8A, aclimatado bobina sello juego
  • 991060 Cavidad T-11A, aclimatado bobina sello juego
Notes [ + ]
  • Installation instructions for the weatherized coil and kit are provided on the applicable weatherization kit product page. Please review carefully.