Serie 3 - cavidad T-17A, buna-N, cartucho juego de sellos

990017007 : Serie 3 - cavidad T-17A, buna-N, cartucho juego de sellos
Technical Features [ + ]

Sun offers replacement seal kits for all cartridge models. These kits include all of the external seals on the cartridge along with installation instructions. Seal kits are available in Buna-N and Viton for all models, along with EPDM and polyurethane for many models. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.

  • The shelf life for this cartridge seal kit is ten years from date of purchase. This date will be printed on the kit packaging.
Cartridge Installation Data [ + ]
Series 3
Cartridge Thread 1"-14 UNS1"-14 UNS
Valve Hex Size 1 1/4 in.31,8 mm
Valve Installation Torque 150 - 160 lbf ft203 - 217 Nm
cavidad T-17A
Used With [ + ]

What models can this kit be used with?

  • CBFA Proporción de pilotaje 3:1 , restrictiva contrabalance válvula
  • CBFB Proporción de pilotaje 1.5:1 , semi-restrictiva contrabalance válvula
  • CBFC Proporción de pilotaje 3:1 , semi-restrictiva contrabalance válvula
  • CBFD Proporción de pilotaje 4.5:1 , semi-restrictiva contrabalance válvula
  • CBFG Proporción de pilotaje 4.5:1 , restrictiva contrabalance válvula
  • CBFL Proporción de pilotaje 2.3:1 , semi-restrictiva contrabalance válvula
  • CBGA Proporción de pilotaje 3:1 , capacidad estándar contrabalance válvula
  • CBGB Proporción de pilotaje 1.5:1 , capacidad estándar contrabalance válvula
  • CBGG Proporción de pilotaje 4.5:1 , capacidad estándar contrabalance válvula
  • CBGH Proporción de pilotaje 10:1 , capacidad estándar contrabalance válvula
  • CBGL Proporción de pilotaje 2.3:1 , capacidad estándar contrabalance válvula
  • CBGY Proporción de pilotaje 2:1 , capacidad estándar contrabalance válvula
  • CKGB Anti-retorno con pilotaje para abrir válvula con piloto estándar
  • CKGD Anti-retorno con pilotaje para abrir válvula con piloto sellado
  • CKGV Anti-retorno venteado con pilotaje para abrir válvula - de referencia atmosférica
  • CNGD Caudal libre del lado a la nariz anti-retorno válvula con orificio de desvió y puerto 3 bloqueado
  • CNGE Anti-retorno con pilotaje para abrir válvula con orificio de desvió
  • CNHE Pilotaje para cerrar anti-retorno válvula con orificio de desvió
  • COHA Pilotaje para cerrar anti-retorno válvula
  • CXGE Caudal libre del lado a la nariz anti-retorno válvula con puerto 3 bloqueado
  • CXHC Caudal libre de nariz al lado anti-retorno válvula con puerto 3 bloqueado
  • DKHC Normalmente cerrado, disco balanceado, elemento lógico - pilotaje para abrir
  • DKHD Normalmente cerrado, disco balanceado, elemento lógico - ventear-para-abrir
  • DOHC Normalmente abierto, disco balanceado, elemento lógico - pilotaje para cerrar
  • DOHD Normalmente abierto, disco balanceado, elemento lógico - ventear-para-cerrar
  • FREA Fixed-orifice, desvió /restrictivo, prioritario, control de caudal válvula
  • LKHC Pilotaje para abrir, spring-biased closed, disco desequilibrado elemento lógico
  • LKHCZ Pilotaje para abrir, spring-biased closed, disco desequilibrado elemento lógico con indicador de posición
  • LOGCZ Pilotaje para cerrar, spring-biased closed, disco desequilibrado elemento lógico con muescas de medición y indicador de posición
  • LOHA Ventear-para-abrir, spring-biased closed, disco desequilibrado elemento lógico con fuente de pilotaje del puerto 1
  • LOHA8 Ventear-para-abrir, spring-biased closed, disco desequilibrado elemento lógico con fuente de pilotaje del puerto 1 y cavidad de control T-8A integral
  • LOHB Ventear-para-abrir, spring-biased closed, disco desequilibrado elemento lógico con fuente de pilotaje del puerto 2
  • LOHB8 Ventear-para-abrir, spring-biased closed, disco desequilibrado elemento lógico con fuente de pilotaje del puerto 2 y cavidad de control T-8A integral
  • LOHC Pilotaje para cerrar, spring-biased closed, disco desequilibrado elemento lógico
  • LOHCZ Pilotaje para cerrar, spring-biased closed, disco desequilibrado elemento lógico con indicador de posición
  • LOHD Ventear-para-abrir, spring-biased closed, disco desequilibrado elemento lógico con fuente de pilotaje del puerto 1 o 2
  • LOHD8 Ventear-para-abrir, spring-biased closed, disco desequilibrado elemento lógico con fuente de pilotaje del puerto 1 o 2 y cavidad de control T-8A integral
  • LOHO Pilotaje para cerrar, spring-biased open, disco desequilibrado elemento lógico
  • LOHOZ Pilotaje para cerrar, spring-biased open, disco desequilibrado elemento lógico con indicador de posición
  • LPHA Normalmente abierto, elementos de modulación con fuente de pilotaje del puerto 1
  • LPHC Normalmente abierto, elementos de modulación
  • LRHA Normalmente cerrado, elementos de modulación con fuente de pilotaje del puerto 1
  • LRHC Normalmente cerrado, elementos de modulación
  • PBHB Pilot-operated, reductor de presión válvula
  • PBHB8 Pilot-operated, reductor de presión módulo principal con cavidad de control T-8A integral
  • PBHC Controlado por aire, pilot-operated, reductor de presión válvula
  • PBHF Pilot-operated, reductor de presión válvula con orificio de pistón barrenado
  • PBHF8 Pilot-operated, reductor de presión módulo principal con orificio de pistón barrenado y cavidad de control T-8A integral
  • PPHB Pilot-operated, reductor/alivio de presión válvula
  • PPHB8 Pilot-operated, reductor/alivio de presión módulo principal con cavidad de control T-8A integral
  • PPHC Controlado por aire, pilot-operated, reductor/alivio de presión válvula
  • PPHF Pilot-operated, reductor/alivio de presión válvula con orificio de pistón barrenado
  • PPHF8 Pilot-operated, reductor/alivio de presión módulo principal con orificio de pistón barrenado y cavidad de control T-8A integral
  • PRHB Acción-directa , reductor/alivio de presión válvula
  • PRHR Acción-directa , reductor de presión válvula
  • RSHC Pilot-operated, pistón balanceado secuencia válvula
  • RSHC8 Pilot-operated, pistón balanceado secuencia módulo principal con cavidad de control T-8A integral
  • RSHE Controlado por aire, pilot-operated, pistón balanceado secuencia válvula
  • RVGA De venteo, pilot-operated, pistón balanceado alivio válvula
  • RVGB Normalmente cerrado elementos de modulación válvula con función de alivio
  • SCGA Acción-directa secuencia válvula con anti-retorno de caudal inverso
  • SQHB Tirar-abajo, pilot-operated, pistón balanceado secuencia válvula
  • XHBA Puerto 1 abierto al 3, puerto 2 bloqueado tapón de cavidad
  • XHCA Todos los puertos bloqueados tapón de cavidad
  • XHOA Puerto 1 abierto al 2, puerto 3 bloqueado tapón de cavidad
  • XHOAE Puertos 1 y 2 al puerto externo, port 3 bloqueado tapón de cavidad
  • XHOB Todos los puertos abiertos tapón de cavidad
  • XHOC Cavidad T-17A a cavidad T-11A convertidor
Notes [ + ]
  • Install back-up rings and O-rings as shown in views.
  • When installing continuous back-up rings, use the same technique and the same care used to install O-rings.
  • When installing cartridge - be sure to torque to recommended value.
Additional Resources [ + ]