ISO 05 X e Y Europa aplilables distribuidor de circuito integrado hidráulico retenedor y buna-N juego de sellos

990120012 : ISO 05 X e Y Europa aplilables distribuidor de circuito integrado hidráulico  retenedor y buna-N juego de sellos
Technical Features [ + ]

Sun ISO 05 X, Y sandwich bodies are furnished with pilot drain ports, and due to the difference in the U.S. and European port locations, two different seal retainer plates are available. The ISO 05 X, Y CETOP seal retainer plate is for use with European manufactured directional valve applications only. Seal retainer plate only, seals only, and combination kits are available.

  • All Sun seal plates are manufactured to current industry standards regarding passages and mounting bolt locations.
  • The ISO 05 X, Y CETOP sandwich body can only be rotated about a single axis. Depending on the rotation of the body in relation to the seal retainer plate, the "A" and "B" passages can be reversed but the "P","T","X", and "Y" passages will remain unchanged.
  • Sun ISO 05 X and Y sandwich bodies contain the drain and pilot passages for both U.S. and European valve manufacturers. The seal plate must be specified and ordered separately to ensure proper drain passage alignment with the rest of the stack.
  • For use with the following European valve products: Rexroth (WEH 10), and Bosch
Technical Data [ + ]
Seal Material Buna-NBuna-N
Material Zinc Plated SteelZinc Plated Steel
Plate Thickness .050 in.1,27 mm
Used With [ + ]

What models can this kit be used with?

  • YDEL Sensible a la presión regenerador ensamblaje
  • YFEX Desvió /restrictivo , control de caudal prioritario con anti-retorno de caudal inverso ensamblaje
  • YFEY Desvió /restrictivo , control de caudal prioritario con anti-retorno de caudal inverso ensamblaje
  • BJ2 ISO 05 - X&Y: Reducer on A with reverse flow check
  • BJ3 ISO 05 - X&Y: Reducer on B with reverse flow check
  • BJ4 ISO 05 - X&Y: Sequence into A or out of B with reverse flow check
  • BJ5 ISO 05 - X&Y: Sequence into B or out of A with reverse flow check
  • BJ8 ISO 05 - X&Y: amortiguar y bloquear
  • BJ9 ISO 05 - X&Y: Reducer on A and B with reverse flow check
  • BJA ISO 05 - X&Y: On A, port 3 to B
  • BJB ISO 05 - X&Y: On B, port 3 to A
  • BJC ISO 05 - X&Y: P to T, port 3 external
  • BJO ISO 05 - X&Y: On P, port 3 to T
  • BJP ISO 05 - X&Y: On P, port 3 to T
  • BJW ISO 05 - X&Y: On P, port 3 to T
  • BJX ISO 05 - X&Y: On A and B, port 3 to T
  • BJY ISO 05 - X&Y: On A and B with cross pilot
  • CJ2 ISO 05 - X&Y: A to T, check T to B
  • CJ4 ISO 05 - X&Y: On A with reverse flow check
  • CJ5 ISO 05 - X&Y: On B with reverse flow check
  • CJA ISO 05 - X&Y: A to T
  • CJB ISO 05 - X&Y: B a T
  • CJC ISO 05 - X&Y: A to B or B to A
  • CJP ISO 05 - X&Y: P to T
  • CJX ISO 05 - X&Y: A and B to T
  • CJY ISO 05 - X&Y: A to B and B to A
  • DJA ISO 05 - X&Y: Flow into workport B or out of A
  • DJB ISO 05 - X&Y: Flow into workport A or out of B
  • DJC ISO 05 - X&Y: Flow into workport A
  • DJD ISO 05 - X&Y: Out of A
  • DJE ISO 05 - X&Y: Flow into workport B
  • DJF ISO 05 - X&Y: fuera de B
  • DJJ ISO 05 - X&Y: Flow into workport B or out of A
  • DJK ISO 05 - X&Y: Flow into workport A or out of B
  • DJL ISO 05 - X&Y: Flow into workports A and B or out of A and B
  • DJN ISO 05 - X&Y: Priority flow control on P, bypass to T
  • DJO ISO 05 - X&Y: On P
  • DJP ISO 05 - X&Y: On P
  • DJR ISO 05 - X&Y: T to A and B
  • DJS ISO 05 - X&Y: A to B or B to A
  • DJT ISO 05 - X&Y: Out of T
  • DJU ISO 05 - X&Y: A to P or B to P
  • DJW ISO 05 - X&Y: T to A and B
  • DJX ISO 05 - X&Y: A and B to T
  • DJY ISO 05 - X&Y: Flow into workports A and B or out of A and B
  • DJZ ISO 05 - X&Y: Flow into workports A and B or out of A and B
  • NJ2 ISO 05 - X&Y: Reducer/reliever on A with reverse flow check and port 4 external
  • NJ3 ISO 05 - X&Y: Reducer/reliever on B with reverse flow check and port 4 external
  • NJA ISO 05 - X&Y: On A, port 3 to B and port 4 to T
  • NJB ISO 05 - X&Y: On B, port 3 to A and port 4 to T
  • NJP ISO 05 - X&Y: On P, port 3 to T and port 4 external
  • NJY ISO 05 - X&Y: On A and B with cross pilot and port 4 to T
  • U8B ISO 05 - X&Y: On A with reverse flow check
  • U8T ISO 05 - X&Y: On B
  • WHY ISO 05 - X&Y: Priority flow control on A with reverse flow check
  • WHZ ISO 05 - X&Y: Priority flow control on B with reverse flow check
  • WJF ISO 05 - X&Y: On P, port 3 to T
  • X8E Blanking plate, P to A and B, T blocked
  • X8K P to A and B, T Blocked
  • Z3F ISO 05 - X&Y: On P, port 3 to T
  • ZFB ISO 05 - X&Y (Euro): P to T, port 3 to Y
  • ZJM ISO 05: Cover manifold, P to A and B to T
  • ZJN ISO 05: Cover manifold, P to T
  • ZJP ISO 05: Cover manifold, all ports blocked
  • ZPP ISO 05 - X&Y: Tap in manifold - A and B
  • ZSQ ISO 05 - X&Y: Tap in manifold - A and B
  • ZSY ISO 05 - X&Y: Tap in manifold - A and B
Additional Resources [ + ]