De estilo de insertar, solo una esfera selector válvula con señal al puerto 2

Capacidad: 1.25 gpm4,7 L/min. | Cavidad: T-162DP
CSAN : De estilo de insertar, solo una esfera  selector válvula  con señal al puerto 2
Technical Features [ + ]

The single ball shuttle connects the higher of two work ports to the signal or common port. The signal is sensed at port 2.

  • This valve is what we call an Insert style. It is meant to be buried in a manifold or actuator. The cavity drawing for the T-162DP cavity contains a lot of detailed information and should be studied closely when applying this valve.
  • Shuttle cartridges feature hardened steel balls and seats for excellent wear characteristics and contamination tolerance.
  • The single ball allows for the decay of the pressure signal when both load ports drop to a lower pressure.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
Technical Data [ + ]
Notar: Los datos pueden variar según la configuración . Consulte la sección de CONFIGURATION
cavidad T-162DP
Series 0
Capacity 1.25 gpm4,7 L/min.
Maximum Operating Pressure 5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 5 drops/min.0,3 cc/min.
Valve Internal Hex Size 5/16 in.8 mm
Valve Installation Torque 20 - 25 lbf ft27 - 33 Nm
Model Weight .20 lb0,10 kg
Seal kit - Cartridge Buna: 990162007
Seal kit - Cartridge Polyurethane: 990162002
Seal kit - Cartridge Viton: 990162006
Performance Curves [ + ]
FAQs [ + ]

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.

Only external seals are serviceable.  Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.