Doble , acción-directa alivio válvula - capacidad de pilotaje

Capacidad: .25 gpm1 L/min. | Cavidad: T-11A
RBAD : Doble , acción-directa  alivio válvula  - capacidad de pilotaje
Technical Features [ + ]

This direct-acting, pilot relief cartridge incorporates back-to-back check valves. This allows it to remotely control 2 other pilot-operated valves or act as a thermal relief for both ends of an actuator. Because capacity is limited to pilot flow, this valve should be used with other valves with comparable pilot flows.

  • The back-to-back check valves prevent cross talk between the two valves that are being remote controlled.
  • One adjustment controls two valves.
  • Check cracking pressure is 15 psi (1 bar).
  • Pressure at port 3 is directly additive to the valve setting.
  • Suitable for load holding applications
  • The term thermal relief means it prevents overpressure due to thermal expansion of the fluid.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
Technical Data [ + ]
Notar: Los datos pueden variar según la configuración . Consulte la sección de CONFIGURATION
cavidad T-11A
Series 1
Capacity .25 gpm1 L/min.
Maximum Valve Leakage at 110 SUS (24 cSt) 5 drops/min.0,3 cc/min.
Response Time - Typical 2 ms2 ms
Adjustment - No. of CW Turns from Min. to Max. setting 55
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size 5/32 in.4 mm
Locknut Hex Size 9/16 in.15 mm
Locknut Torque 80 - 90 lbf in.9 - 10 Nm
Seal kit - Cartridge Buna: 990011007
Seal kit - Cartridge Polyurethane: 990011002
Seal kit - Cartridge Viton: 990011006
Performance Curves [ + ]
FAQs [ + ]

Pressure setting tolerances are listed in our Performance Data page. A link to this page can also be found in the Additional Resources tab of the applicable product page.

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

Maybe not. We build in a good amount of overlap in the kick-down reliefs to prevent false tripping. This means they are not as fast as our standard pilot-operated reliefs. A direct-acting relief valve set just above the kick-down relief valve would be good insurance.

Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.

One graphic example is on a portable grain auger for silos. When the farmer gets caught in the auger the kick-down relief trips and allows him to escape.

Only external seals are serviceable.  Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.
Notes [ + ]
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.
Additional Resources [ + ]