24 VDC explosion proof coil, twin leads, 1/2" NPT conduit connector, ATEX and IECEx certified

777HN24AA : 24 VDC explosion proof coil, twin leads, 1/2
Technical Features [ + ]

Sun offers explosion proof coils for use in hazardous environments. Certification requires the explosion proof coil to be sold as a complete cartridge/coil assembly. Coil cannot be purchased separately. For ordering information, please see the coil option section on the applicable cartridge product page.

  • ATEX certified: II 2 G (See Additional Resources tab below)
  • IECEx certified: Ex mb IIC T3 Gb (See Additional Resources tab below)
  • This coil is CE compliant.
  • Certification requires the explosion proof coil to be sold as a complete cartridge/coil assembly. Coil cannot be purchased separately.
  • For optimum proportional performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 80 - 250 Hz.
  • Ingression protection rating is IP67.
  • RoHS compliant. Restricted materials less than 0.1% total by weight.
  • The external steel shell is zinc plated with yellow dichromate. The coil nut is zinc plated with clear dichromate.
  • Non-resettable integral internal thermal and current fuse protected.
  • No arc suppression diodes in coil.
  • Coil windings utilize NEMA-MW-80, Class F (155 deg C) magnet wire.
  • Coil must be installed on the cartridge with the proper orientation for proper performance. See drawing/instructions.
Technical Data [ + ]
Ambient Temperature Range -58 to 104 °F-58 to 104 °F
Power Consumption (cold) - at rated voltage 22 watts22 watts
Nominal Current 0.93 amps at 68ºF (20ºC), 24 VDC0.93 amps at 68ºF (20ºC), 24 VDC
Diametric Coil Clearance Requirement 2.125 in.53,98 mm
Voltage/Frequency 24 VDC24 VDC
Operating Voltage Range +/- 10% nominal+/- 10% nominal
Current Fuse (non-resettable) 3 amps3 amps
Thermal Fuse (non-resettable) 378 °F192 °C
Duty Cycle Rating 100 %100 %
Connector Twin lead 18 AWG X 10 ft. (3 m), 1/2-14 NPT female conduit connectorTwin lead 18 AWG X 10 ft. (3 m), 1/2-14 NPT female conduit connector
Connector Environment Rating IP67IP67
Lead Wire Rating AWM styles 3289 150°C - 3271 125°C, 600V VW-1 LL30433 CSA CL1251 125°C or CL1503 150°C, XLPE 600V 18 AWGAWM styles 3289 150°C - 3271 125°C, 600V VW-1 LL30433 CSA CL1251 125°C or CL1503 150°C, XLPE 600V 18 AWG
Solenoid Tube Diameter .75 in.19 mm
Coil Nut Torque 6 - 7 lbf ft8 - 9,5 Nm
Model Weight 1.60 lb0,70 kg
Proportional Performance Data [ + ]
Maximum Current 590 mA590 mA
Used With [ + ]

What models can this kit be used with?

  • DAAL
    2-way, solenoid-operated directional spool valve - pilot capacity
  • DAALS
    2-way, soft shift, solenoid-operated directional spool valve - pilot capacity
  • DBAL
    3-way, solenoid-operated directional spool valve - pilot capacity
  • DBALS
    3-way, soft shift, solenoid-operated directional spool valve - pilot capacity
  • DFCA
    2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2
  • DFCB
    2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1
  • DFDA
    2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2
  • DFDB
    2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1
  • DFEA
    2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2
  • DFEB
    2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1
  • DFFA
    2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2
  • DFFB
    2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1
  • DLDA
    2-way, solenoid-operated directional spool valve
  • DLDAS
    2-way, soft shift, solenoid-operated directional spool valve
  • DMDA 3-way, solenoid-operated directional spool valve
  • DMDAS 3-way, soft shift, solenoid-operated directional spool valve
  • DNCA 4-way, 2-position, solenoid-operated directional spool valve with closed transition
  • DNDA 4-way, 2-position, solenoid-operated directional spool valve
  • DNDAS 4-way, 2-position, soft shift, solenoid-operated directional spool valve
  • DNDC 4-way, 3-position, solenoid-operated directional spool valve
  • DNDY 2-position, 6-way, solenoid-operated directional spool valve
  • DNDYS 2-position, 6-way, soft shift, solenoid-operated directional spool valve
  • DTCA
    2-way, direct-acting, solenoid-operated directional blocking poppet valve with overlap
  • DTDA
    2-way, direct-acting, solenoid-operated directional blocking poppet valve
  • DTDAS
    2-way, direct-acting, soft shift, solenoid-operated directional blocking poppet valve
  • DWDA
    3-way, direct-acting, solenoid-operated directional poppet valve
  • FMDA Electro-proportional 3-way flow control valve, meter in
  • FMDB Electro-proportional 3-way flow control valve, meter in
  • FPCC Electro-proportional flow control valve - normally closed
  • FPCH Electro-proportional flow control valve - normally open
  • FPFK Pilot-operated, normally closed, electro-proportional throttle with reverse flow check
  • FPHK Pilot-operated, normally closed, electro-proportional throttle with reverse flow check
  • HDDA 2-way, solenoid-operated directional poppet valve - after check
  • PRDL
    Electro-proportional, direct-acting, pressure reducing/relieving valve with open transition
  • PRDM Electro-proportional, direct-acting, pressure reducing/relieving valve with open transition - high pressure setting with no command
  • PRDN Electro-proportional, direct-acting, pressure reducing/relieving valve, high pressure setting with no command
  • PRDP
    Electro-proportional, direct-acting, pressure reducing/relieving valve
  • PSDL Electro-proportional, direct-acting, pressure reducing/relieving valve with open transition and drain to port 4
  • PSDP Electro-proportional, direct-acting, pressure reducing/relieving valve with drain to port 4
  • RBAN Electro-proportional relief valve - pilot capacity, high pressure setting with no command
  • RBAP Electro-proportional relief valve - pilot capacity
Notes [ + ]
  • Coil/cartridge assembly can be mounted in any position, however, coil orientation on cartridge assembly is critical. Arrows on coil label must face towards coil nut.
  • Coil cannot be purchased separately and must be configured along with the cartridge valve. Please see the applicable cartridge product page for ordering information.
  • Sun's explosion proof coil requires more clearance than 770 series coil. Sun manifolds with more than one cavity may not allow enough clearance for explosion proof coils.
  • For proportional valve applications, the maximum current of 590mA has been established so a proportional valve can function optimally under a variety of ambient temperatures.
Additional Resources [ + ]