24 VDC explosion proof coil, twin leads, 1/2" NPT conduit connector, CSA certified (C and US)
Technical Features [ + ]
Sun offers explosion proof coils for use in hazardous environments. Certification requires the explosion proof coil to be sold as a complete cartridge/coil assembly. Coil cannot be purchased separately. For ordering information, please see the coil option section on the applicable cartridge product page.
- CSA certified (C and US)
- NEC 505: Class I, Zone 1, AEx mb IIC T3
- NEC 500: Class I, Division I, Groups A, B, C and D; Class II, Division I, Groups E, F, and G; Class III, Division I
- CEC/CSA: Ex mb IIC T3
- Certification requires the explosion proof coil to be sold as a complete cartridge/coil assembly. Coil cannot be purchased separately.
- No arc suppression diodes in coil.
- Coil windings utilize NEMA-MW-80, Class F (155 deg C) magnet wire.
- For optimum proportional performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 80 - 250 Hz.
- Ingression protection rating is IP67.
- RoHS compliant. Restricted materials less than 0.1% total by weight.
- The external steel shell is zinc plated with yellow dichromate. The coil nut is zinc plated with clear dichromate.
- Non-resettable integral internal thermal and current fuse protected.
- Coil must be installed on the cartridge with the proper orientation for proper performance. See drawing/instructions.
Technical Data [ + ]
Ambient Temperature Range | -58 to 104 °F-58 to 104 °F |
Power Consumption (cold) - at rated voltage | 22 watts22 watts |
Nominal Current | 0.93 amps at 68ºF (20ºC), 24 VDC0.93 amps at 68ºF (20ºC), 24 VDC |
Diametric Coil Clearance Requirement | 2.125 in.53,98 mm |
Voltage/Frequency | 24 VDC24 VDC |
Operating Voltage Range | +/- 10% nominal+/- 10% nominal |
Current Fuse (non-resettable) | 3 amps3 amps |
Thermal Fuse (non-resettable) | 378 °F192 °C |
Duty Cycle Rating | 100 %100 % |
Connector | Twin lead 18 AWG X 10 ft. (3 m), 1/2-14 NPT female conduit connectorTwin lead 18 AWG X 10 ft. (3 m), 1/2-14 NPT female conduit connector |
Lead Wire Rating | AWM styles 3289 150°C - 3271 125°C, 600V VW-1 LL30433 CSA CL1251 125°C or CL1503 150°C, XLPE 600V 18 AWGAWM styles 3289 150°C - 3271 125°C, 600V VW-1 LL30433 CSA CL1251 125°C or CL1503 150°C, XLPE 600V 18 AWG |
Solenoid Tube Diameter | .75 in.19 mm |
Coil Nut Torque | 6 - 7 lbf ft8 - 9,5 Nm |
Model Weight | 1.60 lb0,70 kg |
Used With [ + ]
What models can this kit be used with?
- DAAL2-way, solenoid-operated directional spool valve - pilot capacity
- DAALS2-way, soft shift, solenoid-operated directional spool valve - pilot capacity
- DBAL3-way, solenoid-operated directional spool valve - pilot capacity
- DBALS3-way, soft shift, solenoid-operated directional spool valve - pilot capacity
- DFCA2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2
- DFCB2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1
- DFDA2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2
- DFDB2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1
- DFEA2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2
- DFEB2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1
- DFFA2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2
- DFFB2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1
- DLDA2-way, solenoid-operated directional spool valve
- DLDAS2-way, soft shift, solenoid-operated directional spool valve
- DMDA 3-way, solenoid-operated directional spool valve
- DMDAS 3-way, soft shift, solenoid-operated directional spool valve
- DNCA 4-way, 2-position, solenoid-operated directional spool valve with closed transition
- DNDA 4-way, 2-position, solenoid-operated directional spool valve
- DNDAS 4-way, 2-position, soft shift, solenoid-operated directional spool valve
- DNDC 4-way, 3-position, solenoid-operated directional spool valve
- DNDY 2-position, 6-way, solenoid-operated directional spool valve
- DNDYS 2-position, 6-way, soft shift, solenoid-operated directional spool valve
- DTCA2-way, direct-acting, solenoid-operated directional blocking poppet valve with overlap
- DTDA2-way, direct-acting, solenoid-operated directional blocking poppet valve
- DTDAS2-way, direct-acting, soft shift, solenoid-operated directional blocking poppet valve
- DWDA3-way, direct-acting, solenoid-operated directional poppet valve
- FMDA Electro-proportional 3-way flow control valve, meter in
- FMDB Electro-proportional 3-way flow control valve, meter in
- FPCC Electro-proportional flow control valve - normally closed
- FPCH Electro-proportional flow control valve - normally open
- FPFK Pilot-operated, normally closed, electro-proportional throttle with reverse flow check
- FPHK Pilot-operated, normally closed, electro-proportional throttle with reverse flow check
- HDDA 2-way, solenoid-operated directional poppet valve - after check
- PRDLElectro-proportional, direct-acting, pressure reducing/relieving valve with open transition
- PRDM Electro-proportional, direct-acting, pressure reducing/relieving valve with open transition - high pressure setting with no command
- PRDN Electro-proportional, direct-acting, pressure reducing/relieving valve, high pressure setting with no command
- PRDPElectro-proportional, direct-acting, pressure reducing/relieving valve
- PSDL Electro-proportional, direct-acting, pressure reducing/relieving valve with open transition and drain to port 4
- PSDP Electro-proportional, direct-acting, pressure reducing/relieving valve with drain to port 4
- RBAN Electro-proportional relief valve - pilot capacity, high pressure setting with no command
- RBAP Electro-proportional relief valve - pilot capacity
Notes [ + ]
- Coil/cartridge assembly can be mounted in any position, however, coil orientation on cartridge assembly is critical. Arrows on coil label must face towards coil nut.
- Coil cannot be purchased separately and must be configured along with the cartridge valve. Please see the applicable cartridge product page for ordering information.
- Sun's explosion proof coil requires more clearance than 770 series coil. Sun manifolds with more than one cavity may not allow enough clearance for explosion proof coils.
- For proportional valve applications, the maximum current of 590mA has been established so a proportional valve can function optimally under a variety of ambient temperatures.
Additional Resources [ + ]
Highlights
Technical Information
- Sun's Floating Style Screw-In Cartridge (1.06 MB)
- Explosion-Proof Coils - CSA Certificate (402.56 KB)
- Nichtelektrische Ventile in explosionsgefährdeter Umgebung (ATEX (78.13 KB)
- CE Declaration of Conformity - XMD 12-2017 (133.69 KB)
- Explosion-Proof Coils - EC Declaration of Conformity (526.09 KB)
- Non-Electrical Valves in Explosive Environment (ATEX Directive 20 (112.41 KB)
- Explosion-Proof Coils - CSA Information (131.93 KB)