Series 3 - T-17A cavity, buna-N, cartridge seal kit

990017007 : Series 3 - T-17A cavity, buna-N, cartridge seal kit
Technical Features [ + ]

Sun offers replacement seal kits for all cartridge models. These kits include all of the external seals on the cartridge along with installation instructions. Seal kits are available in Buna-N and Viton for all models, along with EPDM and polyurethane for many models. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.

  • The shelf life for this cartridge seal kit is ten years from date of purchase. This date will be printed on the kit packaging.
Cartridge Installation Data [ + ]
Series 3
Cartridge Thread 1"-14 UNS1"-14 UNS
Valve Hex Size 1 1/4 in.31,8 mm
Valve Installation Torque 150 - 160 lbf ft203 - 217 Nm
Cavity T-17A
Used With [ + ]

What models can this kit be used with?

  • CBFA 3:1 pilot ratio, restrictive counterbalance valve
  • CBFB 1.5:1 pilot ratio, semi-restrictive counterbalance valve
  • CBFC 3:1 pilot ratio, semi-restrictive counterbalance valve
  • CBFD 4.5:1 pilot ratio, semi-restrictive counterbalance valve
  • CBFG 4.5:1 pilot ratio, restrictive counterbalance valve
  • CBFL 2.3:1 pilot ratio, semi-restrictive counterbalance valve
  • CBGA 3:1 pilot ratio, standard capacity counterbalance valve
  • CBGB 1.5:1 pilot ratio, standard capacity counterbalance valve
  • CBGG 4.5:1 pilot ratio, standard capacity counterbalance valve
  • CBGH 10:1 pilot ratio, standard capacity counterbalance valve
  • CBGL 2.3:1 pilot ratio, standard capacity counterbalance valve
  • CBGY 2:1 pilot ratio, standard capacity counterbalance valve
  • CKGB Pilot-to-open check valve with standard pilot
  • CKGD Pilot-to-open check valve with sealed pilot
  • CKGV Vented pilot-to-open check valve - atmospherically referenced
  • CNGD Free flow side to nose check valve with bypass orifice and port 3 blocked
  • CNGE Pilot-to-open check valve with bypass orifice
  • CNHE Pilot-to-close check valve with bypass orifice
  • COHA Pilot-to-close check valve
  • CXGE Free flow side to nose check valve with port 3 blocked
  • CXHC Free flow nose to side check valve with port 3 blocked
  • DKHC Normally closed, balanced poppet, logic element - pilot-to-open
  • DKHD Normally closed, balanced poppet, logic element - vent-to-open
  • DOHC Normally open, balanced poppet, logic element - pilot-to-close
  • DOHD Normally open, balanced poppet, logic element - vent-to-close
  • FREA Fixed-orifice, bypass/restrictive, priority, flow control valve
  • LKHC Pilot-to-open, spring-biased closed, unbalanced poppet logic element
  • LKHCZ Pilot-to-open, spring-biased closed, unbalanced poppet logic element with position switch
  • LOGCZ Pilot-to-close, spring-biased closed, unbalanced poppet logic element with metering notches and position switch
  • LOHA Vent-to-open, spring-biased closed, unbalanced poppet logic element with pilot source from port 1
  • LOHA8 Vent-to-open, spring-biased closed, unbalanced poppet logic element with pilot source from port 1 and integral T-8A control cavity
  • LOHB Vent-to-open, spring-biased closed, unbalanced poppet logic element with pilot source from port 2
  • LOHB8 Vent-to-open, spring-biased closed, unbalanced poppet logic element with pilot source from port 2 and integral T-8A control cavity
  • LOHC Pilot-to-close, spring-biased closed, unbalanced poppet logic element
  • LOHCZ Pilot-to-close, spring-biased closed, unbalanced poppet logic element with position switch
  • LOHD Vent-to-open, spring-biased closed, unbalanced poppet logic element with pilot source from port 1 or 2
  • LOHD8 Vent-to-open, spring-biased closed, unbalanced poppet logic element with pilot source from port 1 or 2 and integral T-8A control cavity
  • LOHO Pilot-to-close, spring-biased open, unbalanced poppet logic element
  • LOHOZ Pilot-to-close, spring-biased open, unbalanced poppet logic element with position switch
  • LPHA Normally open, modulating element with pilot source from port 1
  • LPHC Normally open, modulating element
  • LRHA Normally closed, modulating element with pilot source from port 1
  • LRHC Normally closed, modulating element
  • PBHB Pilot-operated, pressure reducing valve
  • PBHB8 Pilot-operated, pressure reducing main stage with integral T-8A control cavity
  • PBHC Air-controlled, pilot-operated, pressure reducing valve
  • PBHF Pilot-operated, pressure reducing valve with drilled piston orifice
  • PBHF8 Pilot-operated, pressure reducing main stage with drilled piston orifice and integral T-8A control cavity
  • PPHB Pilot-operated, pressure reducing/relieving valve
  • PPHB8 Pilot-operated, pressure reducing/relieving main stage with integral T-8A control cavity
  • PPHC Air-controlled, pilot-operated, pressure reducing/relieving valve
  • PPHF Pilot-operated, pressure reducing/relieving valve with drilled piston orifice
  • PPHF8 Pilot-operated, pressure reducing/relieving main stage with drilled piston orifice and integral T-8A control cavity
  • PRHB Direct-acting, pressure reducing/relieving valve
  • PRHR Direct-acting, pressure reducing valve
  • RSHC Pilot-operated, balanced piston sequence valve
  • RSHC8 Pilot-operated, balanced piston sequence main stage with integral T-8A control cavity
  • RSHE Air-controlled, pilot-operated, balanced piston sequence valve
  • RVGA Ventable, pilot-operated, balanced piston relief valve
  • RVGB Normally closed modulating element valve with relief function
  • SCGA Direct-acting sequence valve with reverse flow check
  • SQHB Kick-down, pilot-operated, balanced piston sequence valve
  • XHBA Port 1 to 3 open, port 2 blocked cavity plug
  • XHCA All ports blocked cavity plug
  • XHOA Port 1 to 2 open, port 3 blocked cavity plug
  • XHOAE Ports 1 and 2 to external port, port 3 blocked cavity plug
  • XHOB All ports open cavity plug
  • XHOC T-17A cavity to T-11A cavity converter
Notes [ + ]
  • Install back-up rings and O-rings as shown in views.
  • When installing continuous back-up rings, use the same technique and the same care used to install O-rings.
  • When installing cartridge - be sure to torque to recommended value.