Series 3 - T-23A cavity, buna-N, cartridge seal kit

990023007 : Series 3 - T-23A cavity, buna-N, cartridge seal kit
Technical Features [ + ]

Sun offers replacement seal kits for all cartridge models. These kits include all of the external seals on the cartridge along with installation instructions. Seal kits are available in Buna-N and Viton for all models, along with EPDM and polyurethane for many models. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.

  • The shelf life for this cartridge seal kit is ten years from date of purchase. This date will be printed on the kit packaging.
Cartridge Installation Data [ + ]
Series 3
Cartridge Thread M36M36
Valve Hex Size 1 1/4 in.31,8 mm
Valve Installation Torque 150 - 160 lbf ft203 - 217 Nm
Cavity T-23A
Used With [ + ]

What models can this kit be used with?

  • CVGV Vented pilot-to-open check valve
  • CWGA 3:1 pilot ratio, vented counterbalance valve
  • CWGG 5:1 pilot ratio, vented counterbalance valve
  • CWGK 1:1 pilot ratio, vented counterbalance valve
  • CWGL 2:1 pilot ratio, vented counterbalance valve
  • DKHP Normally closed, balanced poppet, logic element - pressure adjustable
  • DKHR Normally closed, balanced poppet, logic element - vent-to-open
  • DKHR8 Normally closed, balanced poppet, logic element with integral T-8A control cavity - vent-to-open
  • DKHS Normally closed, balanced poppet, logic element - pilot-to-open
  • DOHP Normally open, balanced poppet, logic element - pressure adjustable
  • DOHR Normally open, balanced poppet, logic element - vent-to-close
  • DOHR8 Normally open, balanced poppet, logic element with integral T-8A control cavity - vent-to-close
  • DOHS Normally open, balanced poppet, logic element - pilot-to-close
  • FKFA 2-way, pilot-shifted, proportional throttle
  • FKFB 2-way, pilot-shifted, proportional throttle with bleed down
  • FKGA 2-way, pilot-shifted, proportional throttle, high capacity
  • FKGB 2-way, pilot-shifted, proportional throttle with bleed down, high capacity
  • FVEA Ventable, fixed-orifice, bypass/restrictive, priority flow control valve
  • FVEA8 Ventable, fixed-orifice, bypass/restrictive, priority flow control valve with integral T-8A control cavity
  • PSHB Direct-acting, pressure reducing/relieving valve with drain to port 4
  • PSHT Direct-acting, pressure reducing/relieving main stage piloted from port 4
  • PVHA Pilot-operated, pressure reducing/relieving valve with drain to port 4
  • PVHA8 Pilot-operated, pressure reducing/relieving main stage with integral T-8A control cavity and drain to port 4
  • PVHB Ventable, pilot-operated, pressure reducing/relieving valve
  • PVHD Ventable, pilot-operated, pressure reducing/relieving valve with drilled piston orifice
  • PVHL8 Pilot-operated, pressure reducing/relieving main stage with integral T-8A control cavity and drain to port 4
  • RVGD Ventable, pilot-operated, balanced piston relief valve with drain to port 4
  • RVGD8 Ventable, pilot-operated, balanced piston relief main stage with integral T-8A control cavity and drain to port 4
  • XPCA All ports blocked cavity plug
  • XPOA Ports 3 and 4 or port 5 and 6 blocked, all other ports open cavity plug
  • XPOC T-23A cavity to T-21A cavity or T-22A cavity converter
Notes [ + ]
  • Install back-up rings and O-rings as shown in views.
  • When installing continuous back-up rings, use the same technique and the same care used to install O-rings.
  • When installing cartridge - be sure to torque to recommended value.
Additional Resources [ + ]