Direct mount

Function

Function for W6G
Port Designators [ + ]
Modifiers Ports
W6G, /V Ports 1 & 2: 1 1/2" Code 61; Ports 3A & 3B: SAE 6;
W6G/M, /Z Ports 1 & 2: 1 1/2" Code 61; Ports 3A & 3B: 1/4" BSPP;
Technical Data [ + ]
Body Type Line mountLine mount
Interface 1.50 SAE C611.50 SAE C61
Body Features Direct mountDirect mount
Mounting Hole Thread .500-13 UNC - 2B in..500-13 UNC - 2B in.
Mounting Hole Depth 1.06 in.1.06 in.
Mounting Hole Quantity 22
Open Cavities 11
Cavity T-17A
1 1/2" Code 611 1/2" Code 61
FAQs [ + ]

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

Notes [ + ]
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.
Additional Resources [ + ]