Solenoid operated ventable relief assembly

Function

Function for XRGX: Normally Closed
Normally Closed
Function for XRGX: Normally Open
Normally Open
Port Designators [ + ]
Modifiers Ports
4, 4/S Ports 1 & 2: 1" Code 62; Port G: 1/4" NPTF;
4/M, 4/T Ports 1 & 2: 1" Code 62; Port G: 1/4" BSPP;
5, 5/S Ports 1 & 2: 1 1/4" Code 62; Port G: 1/4" NPTF;
5/M, 5/T Ports 1 & 2: 1 1/4" Code 62; Port G: 1/4" BSPP;
D, D/S Ports 1 & 2: 3/4" NPTF; Gage Port: 1/4" NPTF;
E, E/S Ports 1 & 2: 1" NPTF; Gage Port: 1/4" NPTF;
F, F/S Ports 1 & 2: 1 1/4" NPTF; Gage Port: 1/4" NPTF;
L, L/S Ports 1 & 2: SAE 12; Gage Port: 1/4" NPTF;
M, M/S Ports 1 & 2: SAE 16; Gage Port: 1/4" NPTF;
N, N/S Ports 1 & 2: SAE 20; Gage Port: 1/4" NPTF;
P, P/S Ports 1 & 2: 1" Code 61; Port G: 1/4" NPTF;
P/M, P/T Ports 1 & 2: 1" Code 61; Port G: 1/4" BSPP;
Q, Q/S Ports 1 & 2: 1 1/4" Code 61; Port G: 1/4" NPTF;
Q/M, Q/T Ports 1 & 2: 1 1/4" Code 61; Port G: 1/4" BSPP;
W, W/S Ports 1 & 2: 3/4" BSPP; Gage Port: 1/4" BSPP;
X, X/S Ports 1 & 2: 1" BSPP; Gage Port: 1/4" BSPP;
Y, Y/S Ports 1 & 2: 1 1/4" BSPP; Gage Port: 1/4" BSPP;
Technical Features [ + ]

This valve assembly provides 2 functions. It relieves from pressure (port 1) to tank (port 2) when pressure at port 1 exceeds the setting of the valve. The solenoid control allows the valve to be vented, dropping the pressure to a minimal level. This assembly is available in both normally open H option and normally closed C option. The normally open option means the pressure is at a low level until the solenoid is energized. The normally closed option means the pressure is at a high level until the solenoid is energized.

  • This assembly is well suited to loading and unloading a pump.
  • The nature of a vented relief is that it brings the pressure up in a smooth manner. Unloading is abrupt.
  • The DAAL-*** solenoid valve extends approximately 1.18 (normally open valve) and 1.48 inches (normally closed valve) farther out from the manifold than the existing Parker valve. The DAAL-*** solenoid coil is not available with a ½ in. NPTF electrical conduit interface, as was the Parker/Waterman coil. If a ½ in. NPTF conduit interface is required, a DAAL-*** valve coil with ISO/DIN 43650 connector can be converted to ½ in. NPTF conduit interface by using a series P560D connector from Canfield Connectors (see www.canfieldconnector.com for details).
Technical Data [ + ]
Body Type Line mountLine mount
Capacity 60 gpm240 L/min.
Mounting Hole Depth .62 in.15,7 mm
Mounting Hole Quantity 22
FAQs [ + ]

Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

Notes [ + ]
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.
  • For detailed information regarding the cartridges contained in this assembly, click on the models codes shown in the Included Components tab.
Additional Resources [ + ]
Coil Information [ + ]

No coil selected.