Direct mount, cross pilot

Function

Function for YVS
Port Designators [ + ]
Modifiers Ports
YVS, /V Ports C2, V1, V2: SAE 12;
Technical Features [ + ]

Pilot-operated, balanced-piston relief cartridges are normally closed pressure regulating valves. When the pressure at the inlet (port 1) reaches the valve setting, the valve starts to open to tank (port 2), throttling flow to regulate the pressure. These valves are accurate, have low pressure rise vs. flow, they are smooth and quiet, and are moderately fast.

Technical Data [ + ]
Body Type Gasket mountGasket mount
Interface SunSun
Body Features Direct mount, cross pilotDirect mount, cross pilot
Mounting Hole Diameter .53 in.13,5 mm
Mounting Hole Depth ThroughThrough
Mounting Hole C'bore Diameter .78 in.19,8 mm
Mounting Hole C'bore Depth .44 in.11.1 mm
Mounting Hole Quantity 22
Open Cavities 22
Cavity T-17A
Port Size SAE 12SAE 12
FAQs [ + ]

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

Notes [ + ]
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.
Additional Resources [ + ]