Fully adjustable needle valve with reverse flow check

Capacity: 2 gpm (.09 inch)8 L/min. (2,3 mm) | Cavity: T-13A
NCCC : Fully adjustable needle valve with reverse flow check
Technical Features [ + ]

Needle valves with reverse-flow check are fully adjustable orifices used to regulate flow. They are infinitely adjustable from fully closed up to the maximum orifice diameter. An integral high-capacity check valve provides unrestricted flow from port 2 to port 1. They are not pressure compensated.

  • All 2-port flow control cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size). However, cartridge extension dimensions from the mounting surface may vary.
  • Because needle valves are non-compensating devices, the fixed orifice size will regulate flow through the valve in proportion to the square root of the pressure differential across ports 1 and 2.
  • The sharp-edged orifice design minimizes flow variations due to viscosity changes.
Technical Data [ + ]
Note: Data may vary by configuration. See CONFIGURATION section.
Cavity T-13A
Series 1
Capacity 2 gpm (.09 inch)8 L/min. (2,3 mm)
Maximum Operating Pressure 5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 5 drops/min.0,3 cc/min.
Adjustment - No. of CCW Turns from Fully Closed to Fully Open 55
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size 5/32 in.4 mm
Locknut Hex Size 9/16 in.15 mm
Locknut Torque 80 - 90 lbf in.9 - 10 Nm
Model Weight .30 lb0,15 kg
Seal kit - Cartridge Buna: 990010007
Seal kit - Cartridge Polyurethane: 990010002
Seal kit - Cartridge Viton: 990010006
Performance Curves [ + ]
FAQs [ + ]

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

Only external seals are serviceable.  Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.
Notes [ + ]
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.