4 voies , 3 Positions, ISO 4401-03 électro distributeur Dispositif de contrôle Valve - 5000 psi (350 bar)

Capacité: 21.1 gpm80 L/min. | Cavité:
75V307 : 4 voies , 3 Positions, ISO 4401-03 électro distributeur Dispositif de contrôle Valve - 5000 psi (350 bar)
Caractéristiques techniques [ + ]
  • Direct-acting directional control valve with subplate mounting interface per ISO 4401, DIN 24340 (CETOP 03)
  • Compact design with reduced solenoid dimensions
  • Zinc-nickel (ZnNi) coated surface protection for mobile applications (ISO 9227, 520 hour salt spray)
  • High transmitted hydraulic power up to 5100 psi (350 bar) with optimized design to minimize pressure drop
  • Five-chamber housing design with reduced hydraulic power dependence on fluid viscosity
  • The coil is fastened to the core tube with a retaining nut and can be rotated by 360° to suit the available space
  • Includes manual override function (pressure in port T must be less than 363 psi (25 bar) for the spool to shift properly)
Caractéristiques [ + ]
Remarque: Les caractéristiques peuvent changer selon la configuration. Voir la section CONFIGURATION.
Capacité 21.1 gpm80 L/min.
Poids du composant (avec la bobine) 3,5 lb1,6 kg
Plan de Pose Cetop 03Cetop 03
Matière des Joints Buna NBuna N
Ambient Temperature Range -22 to 122 °F-30 to 50 °C
Max. operating press. at ports P,A,B 5080 psi350 bar
Max. operating press. at port T 3050 psi210 bar
Fluid Temperature Range -22 to 176 °F-30 to 80 °C
Response Time -ON 30 - 50 ms30 - 50 ms
Response Time - OFF 10 - 50 ms10 - 50 ms
Performance Curves [ + ]
FAQs [ + ]

Il y a exactement 15 gouttes Sun dans un centimètre cube.

Direct acting valves are used to prevent over pressure and pilot operated valves are used to regulate pressure. If you are unsure, use a direct acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.

Only external seals are serviceable.  Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.
Notes [ + ]
  • In case of solenoid malfunction or power failure, the spool of the valve can be shifted by manual override as long as the pressure in port T does not exceed 363 psi (25 bar).
  • One solenoid must be de-energized before the other solenoid can be charged.
Ressources Complémentaires [ + ]