Technical Features [ + ]

Model 747 Series hazardous location coils are designed for Sun's FLeX Series switching and proportional solenoid valves and for newer Sun valves that use the 16-mm actuator tubes. All models include ATEX, IECEx, and NEC, CEC/CSA certifications.

  • This coil is CE compliant.
  • RoHS compliant. Restricted materials less than 0.1% total by weight.
  • All hazardous location coils are certified for gas and dust environments (T4 compliant for gas and T135° C for dust).
  • IP66 rating (with suitable certified cable entry or conduit per IEC 60529).
  • Includes vibration-resistant push-to-connect terminal block. Power cable with mating connector is required and not included with this product.
  • The external steel shell is zinc-nickel plated (1000-hour salt fog protection).
  • Fin-free design prevents build up of grease, dust and debris.
  • The coil is magnetically symmetrical and can be mounted in either direction on the solenoid tube without affecting performance.
  • A TVS surge suppression diode is built in and offers a 48-Vdc breakdown voltage.
  • For optimum performance when used on a proportional valve, an amplifier with current feedback and adjustable dither should be used. Dither should be adjustable between 80-250 Hz.
  • See "Related Information" for Certification information, or click Full Data Sheet above to download complete details.
Technical Data [ + ]
Operating Temperature Range -40 to 158 °F-40 to 70 °C
Diametric Coil Clearance Requirement 2.36 in.59,4 mm
Fluid Temperature Through Valve (Maximum) 158 °F70 °C
Corrosion Resistance (ASTM B117, ISO 9227 5% saline) 1000 hours salt fog (zinc-nickel)1000 hours salt fog (zinc-nickel)
Power Consumption at 68°F (20°C) cold - at rated voltage 30 watts30 watts
Voltage/Frequency 12 VDC (-15%/+0%)12 VDC (-15%/+0%)
Duty Cycle Rating 100 %100 %
Connector M20 x 1.5 female connectorM20 x 1.5 female connector
Solenoid Tube Diameter .63 in.16 mm
Coil Nut Torque 4.5 lbf in.0,5 Nm
Model Weight 1.80 lb0,80 kg
IP Rating IP66 (with suitable cable entry/conduit)IP66 (with suitable cable entry/conduit)
Used With [ + ]

What models can this kit be used with?

  • DBAF 3-way solenoid-operated directional spool valve - pilot capacity (740 Series)
  • DBAFS 3-way, soft shift, solenoid-operated directional spool valve - pilot capacity (740 Series)
  • DFBD FLeX Series 2-way, 2-stage, solenoid-operated directional poppet valve with reverse flow check - flow 2-1, 3000 psi (210 bar)
  • DFBE FLeX Series 2-way, 2-stage, solenoid-operated directional poppet valve with reverse flow check - flow 2-1, 3000 psi (210 bar)
  • DFBF FLeX Series 2-way, 2-stage, solenoid-operated directional poppet valve with reverse flow check - flow 2-1
  • DFBG FLeX Series 2-way, 2-stage, solenoid-operated directional poppet valve with reverse flow check - flow 2-1
  • DFCI 2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2 (740 Series)
  • DFCJ 2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1 (740 Series)
  • DFDI 2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2 (740 Series)
  • DFDJ 2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1 (740 Series)
  • DFEI 2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2 (740 Series)
  • DFEJ 2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1 (740 Series)
  • DFFI 2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2 (740 Series)
  • DFFJ 2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1 (740 Series)
  • DLDF 2-way, solenoid-operated directional spool valve (740 Series)
  • DLDFS 2-way, soft shift, solenoid-operated directional spool valve (740 Series)
  • DMBD FLeX Series 3-way, solenoid-operated directional spool valve - 3000 psi (210 bar)
  • DMBF FLeX Series 3-way, solenoid-operated directional spool valve
  • DNBD FLeX Series 4-way, 2-position, solenoid-operated directional spool valve - 3000 psi (210 bar)
  • DNBF FLeX Series 4-way, 2-position, solenoid-operated directional spool valve
  • DTAF FLeX Series 2-way, direct-acting, solenoid-operated directional blocking poppet valve
  • DTAFS FLeX Series 2-way, soft shift, solenoid-operated directional poppet valve - pilot capacity
  • DTBF FLeX Series 2-way, direct-acting, solenoid-operated directional blocking poppet valve
  • DTCF 2-way, direct-acting, solenoid-operated directional blocking poppet valve with overlap (740 Series)
  • DTDF 2-way, direct-acting, solenoid-operated directional blocking poppet valve (740 Series)
  • DTDFS 2-way, direct-acting, soft shift, solenoid-operated directional blocking poppet valve (740 Series)
  • DWBF FLeX Series 3-way, direct-acting, solenoid-operated directional blocking poppet valve
  • DWDF 3-way, direct-acting, solenoid-operated directional poppet valve (740 Series)
  • FDEP 2-way, direct-acting electro-proportional, pressure compensated flow control valve with reverse flow check
  • FMDF Electro-proportional 3-way flow control valve, meter in (740 Series)
  • FMDG Electro-proportional 3-way flow control valve, meter in (740 Series)
  • FPBF FLeX Series pilot-operated, normally closed, electro-proportional throttle - flow 2-1
  • FPBG FLeX Series pilot-operated, normally closed, electro-proportional throttle with reverse flow check - flow 2-1
  • FPBI FLeX Series pilot-operated, normally open, electro-proportional throttle - flow 2-1
  • FPBJ FLeX Series pilot-operated, normally open, electro-proportional throttle with reverse flow check - flow 2-1
  • FPBU FLeX Series electro-proportional, blocking poppet throttle - normally closed
  • FREP FLeX Series 3-way, direct-acting, electro-proportional, bypass/restrictive, priority flow control valve
  • PRDF Electro-proportional, direct-acting, pressure reducing/relieving valve with open transition (740 Series)
  • PRDG Electro-proportional, direct-acting, pressure reducing/relieving valve (740 Series)
  • RPEI Electro-proportional relief valve - high pressure setting with no command
  • RVCK FLeX Series 2-stage, solenoid-operated adjustable relief valve, normally vented
  • RVCL FLeX Series 2-stage, solenoid-operated adjustable relief valve, energize to vent
  • RVCM FLeX Series 2-stage, solenoid-operated adjustable relief valve, energize to block
  • RVCN FLeX Series 2-stage, solenoid-operated adjustable relief valve, normally blocked
  • 991711300 XMD Series, 12-pin Deutsch prototype cable, single-output - 3M
  • 991711600 XMD Series, 12-pin Deutsch prototype cable, single-output - 6M
  • 991712300 XMD Series, 12-pin Deutsch prototype cable, double-output - 3M
  • 991712600 XMD Series, 12-pin Deutsch prototype cable, double-output - 6M
  • XMD-01 Configurable single-output driver used with proportional and solenoid-operated switching valves
  • XMD-02 Configurable double-output driver used with proportional and solenoid-operated switching valves
Notes [ + ]
  • 1. Mount coil onto spool (tube) body.
  • 2. A cable entry hole is provided to accommodate any suitable certified flameproof cable entry device. Cable entry temperature may exceed 70° C (158° F).
  • 3. Remove terminal box cover and connect electrical supply and earth to terminal block. Conductors according to Note 4. Note: coil is polarity insensitive. The center terminal is the internal ground. Replace cover and secure with the four screws (M4 x ,7). Torque to min 1.92
  • 4. Connect external ground. North American applications: external earth (ground) connections. Use where local codes or authorities permit or require external earth (ground) connections. Torque to 1.25 ft-lbs (1.7 N-m).
  • 5. When installing with multiple coils, the coils must be spaced a minimum of 0.875" (22.23 mm) apart to ensure adequate heat dissipation.
  • For proportional valve applications, the maximum current of 590mA has been established so a proportional valve can function optimally under a variety of ambient temperatures.
  • For installation in above-ground electrical systems in explosive atmospheres, procedures for all applicable codes must be observed. All work must be carried out by an electrician with adequate qualifications for hazardous locations.
Additional Resources [ + ]