Red detent/lock operation, manual override control kit, L control

991241 : Red detent/lock operation, manual override control kit, L control
Technical Features [ + ]

The Twist/Lock manual override is a rotary, hand-actuated device for use on Sun's full flow solenoid valves and certain Series P models. The hand knob is constructed of a reinforced red plastic for durability, heat resistance and stability in varying environmental conditions and is suitable for operation with a gloved hand. The override assembly incorporates a sealed-construction design thereby preventing the introduction of debris and other damaging contamination. Once installed on a Sun solenoid valve, the override feature allows the operator to manually shift the de-energized valve. The red L control is available in kit form only and cannot be configured with the cartridge. Please note that valves with the Twist/Lock manual override are not suitable for load holding applications.

  • The detent/lock override option "L" allows the operator to shift the valve into a mechanically detented position by twisting the manual override counter-clockwise. This detented position will be maintained until the operator twists the manual override clockwise and allows the valve to return to its de-energized position. Please note that the detented position is not suitable for load holding applications.
  • The manual control assembly has a mechanical life expectancy of approximately 7,000 cycles.
Technical Data [ + ]
Material Red plastic and aluminumRed plastic and aluminum
Description Detent/Lock Operation (Option L)Detent/Lock Operation (Option L)
Operating Torque 10 lbf in.1,2 Nm
Used With [ + ]

What models can this kit be used with?

  • DNDYS 2-position, 6-way, soft shift, solenoid-operated directional spool valve
  • FMDA Electro-proportional 3-way flow control valve, meter in
  • FMDB Electro-proportional 3-way flow control valve, meter in
  • FPCC Electro-proportional flow control valve - normally closed
  • FPCH Electro-proportional flow control valve - normally open
Notes [ + ]
  • Ensure o-ring is installed in bottom of the manual override assembly.
  • Remove existing coil nut from end of solenoid tube.
  • Thread the manual override assy on to the end of the solenoid tube. Point coil connector in desired position before hand tightening the manual override assy.
  • Note: Thread lock may be used if anticipated conditions warrant.