Sun offers replacement seal kits for all cartridge models. These kits include all of the external seals on the cartridge along with installation instructions. Seal kits are available in Buna-N and Viton for all models, along with EPDM and polyurethane for many models. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.

  • The Series 2, two port cavity comes in two versions: the T-3A and the T-5A. The T-3A cavity is typically used in relief applications which require larger port areas, hence a deeper cavity. The T-5A cavity is typically used in flow control applications and utilizes a smaller port area. Since both cavities are Series 2, two port, they share common seal kits, but exclude the possibility of cartridge interchangeability between the two functions.
  • The shelf life for this cartridge seal kit is twenty years from date of purchase. This date will be printed on the kit packaging.
Cartridge Installation Data [ + ]
Series 2
Cartridge Thread 1"-14 UNS1"-14 UNS
Valve Hex Size 1 1/8 in.28,6 mm
Valve Installation Torque 45 - 50 lbf ft61 - 68 Nm
cavidad T-3A & T-5A
Used With [ + ]

What models can this kit be used with?

  • CNEC Fixed-orifice, no compensado por presión , control de caudal válvula con anti-retorno de caudal inverso
  • CNFC Caudal libre de nariz al lado anti-retorno válvula con orificio de desvió
  • CXED Caudal libre del lado a la nariz anti-retorno válvula
  • CXFA Caudal libre de nariz al lado anti-retorno válvula
  • CXFHZ Caudal libre de nariz al lado anti-retorno válvula con indicador de posición
  • DFDA
    2-vías , 2-stage, direccional, operada por solenoide disco válvula - caudal 1-2
  • DFDA8 2-vías , disco direccional válvula con cavidad de control T-8A integral - control 1-2
  • DFDB
    2-vías , 2-stage, direccional, operada por solenoide disco válvula - caudal 2-1
  • DFDB8 2-vías , disco direccional válvula con cavidad de control T-8A integral - control 2-1
  • FCDB Fixed-orifice compensado por presión control de caudal válvula con anti-retorno de caudal inverso
  • FDCB Totalmente ajustable compensado por presión control de caudal válvula con anti-retorno de caudal inverso
  • FLFA Filtro
  • FPFK Pilot-operated, normalmente cerrado, electro-proporcional estrangulación con anti-retorno de caudal inverso
  • FQEA Fixed-orifice, fusible de caudal válvula
  • FXDA Fixed-orifice, compensado por presión control de caudal válvula
  • FXDA8 De venteo fixed-orifice, compensado por presión control de caudal válvula con cavidad de control T-8A integral
  • NCEB Totalmente ajustable aguja válvula con anti-retorno de caudal inverso
  • NCEC Totalmente ajustable aguja válvula con anti-retorno de caudal inverso
  • NFDC Totalmente ajustable aguja válvula
  • NFDD Totalmente ajustable aguja válvula
  • NQEB Purga de aire y poner en marcha válvula
  • RBAA Acción-directa alivio válvula - capacidad de pilotaje
  • RBAB Controlado por aire, acción-directa alivio válvula - capacidad de pilotaje
  • RGFA Low-pressure-range, acción-directa alivio válvula
  • RPGC Pilot-operated, pistón balanceado alivio válvula
  • RPGC8 Pilot-operated, pistón balanceado alivio módulo principal con cavidad de control T-8A integral
  • RPGD Controlado por aire, pilot-operated, pistón balanceado alivio válvula
  • RPGE Acción-rápida , pilot-operated, pistón balanceado alivio válvula
  • RQGB Tirar-abajo, pilot-operated, pistón balanceado alivio válvula
  • SCEB De referencia atmosférica , acción-directa secuencia válvula con anti-retorno de caudal inverso
  • XCCA Todos los puertos bloqueados tapón de cavidad
  • XCOA Todos los puertos abiertos tapón de cavidad
Notes [ + ]
  • Install back-up rings and O-rings as shown in views.
  • When installing continuous back-up rings, use the same technique and the same care used to install O-rings.
  • When installing cartridge - be sure to torque to recommended value.
  • During 1985, SUN made a running change of all external seals on Series 2 cartridges (1-1/8 in. (28,6 mm) hex, 1-14 thd). The seals were changed from 3/32 in. (2,62 mm) c/s to 1/16 in (1,7/8 mm) c/s o-rings and backup rings.
  • Use the kit which contains the same size (c/s) seals as those used on the cartridge being repaired. Do not change cartridge o-ring c/s sizes.