Eaton/Char-Lynn 4000/6000: Meter out A and B

Function

Function for VGS
Port Designators [ + ]
Modifiers Ports
VGS, /V All Ports: 3/4" Code 61;
VGS/M, /Z All Ports: 1/2" Code 61;
Technical Features [ + ]

Pilot-operated, balanced-piston relief cartridges are normally closed pressure regulating valves. When the pressure at the inlet (port 1) reaches the valve setting, the valve starts to open to tank (port 2), throttling flow to regulate the pressure. These valves are accurate, have low pressure rise vs. flow, they are smooth and quiet, and are moderately fast.

Technical Data [ + ]
Body Type Motor mountMotor mount
Interface Eaton/Char-Lynn 4000/6000Eaton/Char-Lynn 4000/6000
Body Features Meter out A and BMeter out A and B
Open Cavities 22
Cavity T-5A
Port Size 3/4" Code 613/4" Code 61
FAQs [ + ]

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

Notes [ + ]
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.