Direct mount

Function

Function for Z3C
Port Designators [ + ]
Modifiers Ports
Z3C, /V Ports 1 & 2: 1" Code 61; Ports 3 & 4: SAE 6;
Z3C/M, /Z Ports 1 & 2: 1" Code 61; Ports 3 & 4: 1/4" BSPP;
Technical Data [ + ]
Body Type Line mountLine mount
Interface 1.00 SAE C611.00 SAE C61
Body Features Direct mountDirect mount
Open Cavities 11
Cavity T-23A
1" Code 611" Code 61
FAQs [ + ]

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

Notes [ + ]
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.
Additional Resources [ + ]