2-way, solenoid-operated directional poppet valve - common cavity

Capacity: 16 gpm60 L/min. | Cavity: SC-10-02
DGUA : 2-way, solenoid-operated directional poppet valve - common cavity
Technical Features [ + ]

This solenoid-operated, 2-way, 2-position cartridge is a pilot-operated, directional poppet valve. This valve offers 2-position/2-way directional control with a lower pressure drop than its direct-acting counterpart. The valve is available in the normally open and normally closed condition.

  • This valve is not suitable for load-holding. Up to 9 in³/min (147 mL/min) of leakage is allowed when below a pressure differential of 1600 psi (110 bar) between its ports.
  • The solenoid tube assembly is fatigue rated for 5000 psi (350 bar) service.
  • All ports are rated to a maximum operating pressure of 5000 psi (350 bar).
  • The valve is available with a manual unscrew-type override option (L control) on the normally closed configuration. This option is also fatigue rated for 5000 psi (350 bar).
  • The valve is available with a manual push-type, with detent, override option (L control). This option is also fatigue rated for 5000 psi (350 bar).
  • The metal coil nut is a functional feature of the valve and should be correctly installed for proper performance of the valve.
  • Coil connector options offer ratings up to IP67. See individual coil product pages for details.
  • The cartridge installation torque of 30 lbf ft (40 Nm) is required for best performance.
  • Coils can be mounted on the tube in either direction.
Technical Data [ + ]
Note: Data may vary by configuration. See CONFIGURATION section.
Cavity SC-10-02
Series 1C
Capacity 16 gpm60 L/min.
Maximum Operating Pressure 5000 psi350 bar
Typical Valve Leakage at 110 SUS (24cSt) 15 drops/min.@1600 psi15 drops/min.@1600 psi
Response Time - Typical 300 ms300 ms
Solenoid Tube Diameter .75 in.19 mm
Valve Hex Size 1.00 in.25,4 mm
Coil Nut Torque 3.5 - 3.9 lbf ft4,8 - 5,3 Nm
Valve Installation Torque 29 - 31 lbf ft39 - 42 Nm
Model Weight .62 lb.62 lb
Seal kit - Cartridge Buna: 99C102007
Seal kit - Cartridge Viton: 99C102006
Performance Curves [ + ]
FAQs [ + ]

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.

Only external seals are serviceable.  Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.
Additional Resources [ + ]
Coil Information [ + ]

No coil selected.